Access the device's web interface via a browser
System configuration and monitoring are performed via a web interface. To access the web interface, enter your system's IP address or name in your browser's address bar.
Please use Firefox, Chrome, or Safari as your web browser. The interface is based on HTML5, which is not fully supported by Internet Explorer.
- Open your browser.
- Enter the device's IP address into your browser.
- Press Enter to open the page.
Default network settings
The factory network settings of the devices:
| Parameter | Factory setting |
|---|---|
| DHCP client | switched off |
| Hostname | Didactum |
| IP address of older devices | 192.168.0.193 |
| IP address of the "T" series (50T, 100T, 300T, 500T, 550T, PDU 4M, PDU 4T and PDU 8T) | 192.168.0.101 |
| Network mask | 255.255.255.0 |
| Broadcast | 192.168.0.1 |
| Gateway | 192.168.0.255 |
| Primary DNS | 192.168.0.1 |
To use the device, your PC must be on the same network as the new device. Please configure the following on your PC:
Subnet mask: 255.255.255.0
IP address: 192.168.0.XXX, where XXX is a number from 0 to 192 or from 194 to 254.
To configure the network settings on your PC:
Windows >> Start >> Control Panel >> Network Connections >> Right-click on your LAN connection >> Properties >> Double-click on Internet Protocol (TCP/IP).